The Operating Procedures Of Mortar Spraying Machine

Summary: Mortar spraying machine is also called rapid mortar spraying machine, mixed mortar spraying machine, wall spraying machine. What are the safe operating rules for mortar spraying machine?

is also called rapid mortar spraying machine, mixed mortar spraying machine, wall spraying machine. What are the safe operating rules for mortar spraying machine?


彩神ll用户登录 1. Before starting the mortar spraying machine. First press the gasoline pump to drop the oil to the position of the transmission system several times.

2. After accessing the switching power supply, first electric main motor. Check whether the helical rotation directions of the vulcanized rubber are the same, if not. It is necessary to replace the phase line of the switching power supply (this check must be carried out every time the line is plugged in again).

3. Connect the transport plastic hose and nozzle, add 5L of cold water to the silo. Start the motor to pump the clean water out to the wet bin. The pump casing and the plastic hose for transportation will shut down after pumping out most of the water.

4. Start the air compressor first and open the electric air valve. Adding putty powder or architectural paint to the silo can start spraying.

彩神ll用户登录 5. It is forbidden to rotate at high speed without material or water in the silo.

彩神ll用户登录 6. At the end of the work, the corners of the silo should be emptied, and sufficient cold water should be injected into the silo. Clean the silo and start the pump out. Clean the plastic hoses and nozzles until the pump is cold water. In order to prevent the corner material from condensing in the plastic hose, blocking the plastic hose and the nozzle.

The Operating Procedures Of Mortar Spraying Machine


7. If the shutdown time is too long, scrub the equipment neatly. And remove the additional screw, after oiling. Store properly and reinstall when applied.

8. The working pressure of the pump is insufficient during work. It can be adjusted to increase the anchor bolts of the motor stator or disassemble to increase the buffer block and increase the vortex rod.

彩神ll用户登录 9. Before spraying, tap water should be infiltrated into the total sprayed area. When spraying, the nozzle should be as vertical as possible and the spray surface (the distance can be adjusted independently according to the actual effect of spraying). The wall is too dry or the time after spraying is too long will seriously harm the actual effect of leveling, and the processing technology must be changed

10. The feeding of materials into the silo should be well-balanced and cannot be interrupted. When the transportation screw rotates, it is forbidden to use a stick to mix in the silo to prevent death

11. If the anchor nozzle is blocked, change the power switch to the manual position. Only turn on the refrigeration compressor and remove the quick plug connector on the front of the pump head. Then plug the nozzle downward, and the air pressure will cause the working pressure in the opposite direction. Blow out the residual slurry in the pipeline, and install the quick-connecting joints. At the beginning, everything works normally.

彩神ll用户登录 12. The safety helmet should be worn during the actual operation of the sprinkler. Protective equipment such as goggles and protective clothing

彩神ll用户登录 13. Add buffer block and screw as spare parts, in order to increase the service life. In the first application, the increase of the motor stator anchor bolt is more loose. When the working pressure is reduced and the total flow rate is significantly reduced, adjust the anchor bolts. The place is in all normal working conditions.